Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable

Product Details
Customization: Available
Type: Insulated
Conductor Type: Solid
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (24)
  • Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable
  • Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable
  • Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable
  • Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable
  • Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable
  • Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable
Find Similar Products

Basic Info.

Model NO.
Mulit Core Copper
Application
Overhead, Heating, Underground
Conductor Material
Copper Clad Aluminum
Sheath Material
PVC
Insulation Material
Rubber
Material Shape
Round Wire
Certification
ISO9001, CE, CCC, RoHS, VDE
Brand
Huacheng
Simple
Free
Transport Package
Flexible or Drum Packing
Specification
Tpye-W, Type-G, Type G-Gc
Trademark
huacheng
Origin
China
HS Code
8544492100
Production Capacity
100000000

Product Description

  1. System    
    This product is suitable for transmitting electric energy in power lines with AC 50Hz and rated voltage 0.6/1kV (system maximum voltage 1.2kV).
    Occasion
    Fixed laying in metallurgy, electric power, construction and other industries indoors, cable trenches, pipelines, direct burial and other places that do not need to withstand mechanical external force.
    Product Characteristics
    The raw materials for product production are widely sourced and cheap, and are easy to process and manufacture.
    The product is insulated with cross-linked polyethylene. Compared with PVC insulated cables, it has better insulation performance and canwithstand extremely high working temperatures, up to 90 degrees.
    The product is armored with steel tape and can withstand greater mechanical pressure.
    Using features
    Rated voltage
    The rated voltage is 0.6/1kV, and the maximum voltage of the AC system should not exceed 1.2kV.
    Operating temperature
    The maximum allowable long-term operating temperature of the cable conductor is 90°C; In the case of short circuit, the maximum temperature of the cable conductor shall not exceed 250 ° C and the duration shall not exceed 5s.
    ambient temperature
    The minimum ambient temperature for cable operation is -15ºC.
    Laying temperature
    When installing and laying, the temperature should not be lower than 0ºC.
    bending radius
    The bending radius of single-core cables should be no less than 20 times the outer diameter of the cable, and the bending radius of multi-core cables should be no less than 15 times the outer diameter of the cable.
    Product Identification
    Core of cable
    1.Color identification When multi-core cables are marked with different colors, they must comply with the following regulations: 2-core cable: red, blue; 3-core cable: yellow, green, red; 4-core cable: yellow, green, red, blue; 5-core cable Cable: yellow, green, red, blue, black (or determined by negotiation between the supplier and the buyer). The colors red, yellow and green are used for the main wire core. Blue is used for the neutral core. In order to avoid confusion with other colors, it is recommended to use light blue.
    2. Digital identification When multi-core cables use digital identification, they must comply with the following regulations: 2-core cable: 0, 1; 3-core cable: 1, 2, 3; 4-core cable: 0, 1, 2, 3; 5-core cable :0,1,2,3,4. The numbers 1, 2, and 3 are used for the main core, and 0 is used for the neutral core. In a 5-core cable, the number "4" refers to the specific purpose conductor (including the grounding conductor). When the insulated cores are marked with numbers, the insulation should be of the same color and arranged according to the numbers. Numbers should be printed on the surface of the insulated core with Arabic numerals. The color of the numbers should be the same and have obvious contrast with the insulation color and the writing should be clear; the number signs should be repeated at equal intervals along the insulated core, and two adjacent sets of number signs should be Invert each other. When the logo consists of a single number, a dash should be placed below the number. If the The logo consists of two numbers, it should be arranged up and down and a dash should be placed below the subsequent numbers. The spacing between two adjacent sets of digital logos is d. Should be no larger than 50mm.
    Sheath
    The outer sheath of the cable is usually black, but it can also be in colors other than black according to the manufacturer or buyer's agreement to adapt to its use environment. The cable should have continuous identification of the manufacturer's name, product model and rated voltage . The manufacturer's name identification can be Duplicate identification of manufacturer or trademark. The printed logo should be scratch-resistant and not fall off, and the printed content on the surface should be clearly legible. Note: The logo on the surface of the sheath can also add other logo contents according to the habits of the user or manufacturer.
    Delivery and Tolerance
    Delivery Length
    Cables weighing less than 80kg are allowed to be delivered in coils, and the delivery length of short-segment cables should not exceed 5% of the total delivery length, or cables of any length can be delivered according to mutual agreement.
    Delivery and Tolerance
    Delivery length measurement error is ±0.5%
    Order Instructions

    When ordering, the cable model, specification, length, delivery date, packing method and other necessary information should be correctly marked. For example:
    Model: YJV
    Specification: 3×16
    Length: 1000m
    Packing method: iron tray packing
    Delivery date: last day valid
    Mode of transport: train transport, car transport, ship transport or air transport
    Place of delivery: buyer's warehouse or site or buyer's own delivery
    Note: The mode of transportation and place of delivery shall be specified by the buyer.
    Installation Notice
    During installation, the ambient temperature should not be lower than 0 ° C. If the ambient temperature measured by the thermometer is lower than 0 ° C, preheat the cable before preparing for installation. The bending radius during cable laying should be strictly controlled to avoid mechanical damage inside the cable.

2 Core 4sqmm Solar PV Cable / Twin Core PV Cable /10awg pv wire RPVU90 

Solar Cable

Application

Double insulation, electron-beam cross-linked cables for photovoltaic power station.

Especially for the connection between Solar power generation device connector and connection of inverter,Under the condition of different climate outdoor installation,and can adapt to the dry and wet indoor working environment


Construction
Conductor: Tinned copper, according to the VDE 0295/ IEC 60228,Class5
Insulation: Polyolefin copolymer electron-beam cross-linked
Outer Sheath: Polyolefin copolymer electron-beam cross-linked
Sheath color: Black/Red/Blue or as per customer's requeit


Technical Specification
Nominal Votage: U0/U=600/1000VAC,1000/1800VDC
Test Voltage: 6500V,50Hz,5min
Temperature Rating:
-45ºC ~ +125ºC
-40°F ~ +257°F
Ambient temperature
-40ºC ~ +90ºC
-40°F ~+194°F
Max. Short circuit temperature:280ºC,+536°F
Bending Radius: Fixed installation>4X,  Occasionally moved>5X


Material Properties/ Standards
Fire-resistance performance: IEC 60332-1
Smoke emission: IEC 61034; EN 50268-2
Low fire load: DIN 51900
Approvals: TUV 2PfG 1169/08.2007 PV1-F
Application standards: UNE 211 23; UNE 20.460-5-52,UTE C 32-502 

 

Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable
Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable

 

  Conductor Construction Conductor ø Outer ø Resistance Max. Current Carring Capacity
n×mm² n/m mm mm Ω/Km A
1×1.5 30/0.25 1.58 4.9 13.3 30
1×2.5 50/0.25 2.02 5.45 7.98 41
1×4.0 56/0.3 2.30 6.1 4.75 55
1×6.0 84/0.30 3.42 7.2 3.39 70
1×10.0 142/0.30 4.56 9 1.95 98
1×16.0 228/0.30 5.60 10.2 1.24 132
1×25.0 361/0.30 6.95 12 0.795 176
1×35.0 525/0.30 8.74 13.8 0.565 218
1×50.0 720/0.30 9.20 14.8 0.393 280
1×70.0 988/0.30 11.00 16.9 0.277 350
1×95.0 1349/0.30 12.50 18.7 0.21 410
1×120 1691/0.30 14.20 20.7 0.164 480
 
 
Zhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power CableZhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power CableZhujiang LV Mulit Core Copper Conductor XLPE Insulation PVC Sheath Swa Power Cable